Eclipse Low Pressure Proportional Mixers |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
These mixers are commonly used for glory holes, but can also be used for furnaces and garages when available gas pressure is too low for other burners. They will efficiently mix any commercially available fuel gas from 4"w.c. to 16 oz. with air from 2.5 oz through 4 psi. They also provide single valve control. Please refer to our glory hole size table for recommended BTU information. This table shows Maximum BTU/HR ratings with regards to Mixer Model #, Gas Type, and Fan Pressure Understanding
Glory Hole Combustion (article with illustrations) |
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
LP (Basic) Assembly includes mixing tee, air jet and venturi sleeve. LPB Assembly includes LP assembly plus a butterfly valve. LPG Assembly includes LP assembly plus a zero governor and a gas cock. LPBG Assembly includes LP assembly plus a butterfly valve, zero governor and a gas cock. Please allow at least 3 to 4 weeks lead time. Prices and lead times are subject to change without notice.
The tables above are copyright Wet Dog Glass, LLC, May 2000 Data on these tables comes from Eclipse Combustion Selection Tables 652-3 and 652-4. When ordering, please specify model number, gas type, fan pressure, and BTU's required. If you need assistance, feel free to email us with questions. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||