Eclipse Low Pressure Proportional Mixers

These mixers are commonly used for glory holes, but can also be used for furnaces and garages when available gas pressure is too low for other burners. They will efficiently mix any commercially available fuel gas from 4"w.c. to 16 oz. with air from 2.5 oz through 4 psi. They also provide single valve control.

Please refer to our glory hole size table for recommended BTU information.

This table shows Maximum BTU/HR ratings with regards to Mixer Model #, Gas Type, and Fan Pressure

Understanding Glory Hole Combustion (article with illustrations)

BTU/HR ratings x 1000

Mixer Model #

Gas Type

 Fan Pressure in Ounces

2.5oz 4oz 6oz 8oz 10oz 12oz 16oz

64-LP

Natural 100 200 200 200 200-300 200-300 200-400
Propane 150 150-250 150-250 150-300 200-350 200-350 200-450

84-LP

Natural 200-400 300-500 300-700 300-700 400-700 400-700 500-700
Propane 200-400 300-450 300-500 350-550 400-600 400-750 500-1000

Dimensions and Prices

Mixer Model #

 

Gas Inlet Size

 

Air Inlet Size

Mixture Outlet Size

Prices

LP LPB LPG LPBG
64-LP 1" N.P.T 1-1/2" N.P.T 1-1/2" N.P.T $195.00 $311.22 $627.20 $764.90
84-LP 1" N.P.T 2" N.P.T 2" N.P.T $295.00 $420.29 $838.99 $934.18

 

LP (Basic) Assembly includes mixing tee, air jet and venturi sleeve.

LPB Assembly includes LP assembly plus a butterfly valve.

LPG  Assembly includes LP assembly plus a zero governor and a gas cock.

LPBG Assembly includes LP assembly plus a butterfly valve, zero governor and a gas cock.

Please allow at least 3 to 4 weeks lead time.

Prices and lead times are subject to change without notice.

 

The tables above are copyright Wet Dog Glass, LLC, May 2000

Data on these tables comes from Eclipse Combustion Selection Tables 652-3 and 652-4.

When ordering, please specify model number, gas type, fan pressure, and BTU's required.

If you need assistance, feel free to email us with questions.